Winter Reset integrates ablative CO₂ resurfacing with non-ablative 1570 nm thermal stimulation in one protocol. This combination supports both surface-level renewal and deeper tissue response within a structured treatment approach.
-
Winter Reset is intended for patients who are clinically suitable for deeper resurfacing and are prepared for the associated downtime and recovery process. Final candidacy should always be determined through physician evaluation.
-
Because Winter Reset involves deeper resurfacing and expected recovery time, many clinics prefer scheduling it during periods of reduced sun exposure and social activity. Treatment timing should always be based on clinical judgment and patient circumstances.
-
Downtime reflects the depth of treatment and the biological response involved. Recovery timelines vary based on indication, treatment parameters, and individual healing capacity.
-
Winter Reset is a resurfacing protocol performed on the Alma Hybrid platform. It combines higher-parameter CO₂ with 1570 nm thermal stimulation to support deeper resurfacing and structural remodeling within a defined treatment framework.
-
Yes. Winter Reset may serve as the advanced step within a progressive resurfacing pathway, following lighter interventions, like Pixel Peel, when patient readiness and clinical indication align.
-
Pixel Peel is a low-parameter CO₂ resurfacing protocol performed on the Alma Hybrid platform. It is designed to support repair-focused skin renewal within a structured treatment framework.
-
No. Winter Reset is performed exclusively on the Alma Hybrid platform, utilizing its integrated CO₂ and 1570 nm technologies within one system.
-
Pixel Peel may be suitable for patients seeking visible skin refinement with shorter recovery time. Final candidacy should always be determined through physician evaluation.
-
Pixel Peel is designed as a lighter resurfacing protocol and may be incorporated throughout the year based on clinical assessment, patient indication, and environmental considerations.
-
Pixel Peel utilizes lower CO₂ parameters to reduce treatment intensity and downtime, making it suitable as an entry-level resurfacing option while maintaining the clinical benefits of CO₂ technology.
-
Downtime is typically shorter compared to deeper resurfacing protocols, though recovery varies depending on indication, parameters, and individual healing response.
-
Yes. Pixel Peel may serve as the entry step within a progressive resurfacing pathway, allowing patients to advance to deeper protocols, such as Winter Reset, when readiness and clinical indication align.
-
No. Pixel Peel is performed exclusively on the Alma Hybrid platform using its integrated CO₂ technology.
-
The skin ablation/ non ablation ratio can be customized in a matrix of the precise proportions required to meet the unique treatment needs of each and every patient. Choose from 1:1, 1:2, 1:3, 2:1 and 3:1.
-
Yes, both a histology paper and a clinical paper have been written about the HyGrid, the latter focusing on its use for periorbital rejuvenation.
-
Variable scanning sizes are available, including a mini-grid and a random brush mode.
-
This device features dual laser with a unique lasing pattern in a side by-side grid for both wavelengths.
-
Since each country has different regulations on the subject, please refer to your local regulations regarding the operation of medical devices.
-
Yes. Alma Hybrid is CE marked and FDA approved.
-
Yes. Please refer to the Clinical Resources section above
-
Yes. Using the CO2 laser alone with the HyLight applicator will enable you to perform a variety of surgical applications, such as ablation, vaporization, excision, incision, and
coagulation of soft tissue. -
The ThermoTight applicator is used with low power CO2 laser beam delivery, for dermal heating. It creates a thermal effect as it has a unique defocus lens that
prevents ablation. It was designed to provide gentle and pleasant heat for the treatment of skin laxity. The treatment is monitored by an external thermometer. -
The Alma Hybrid system with the Impact applicator is intended to create acoustic pressure above the skin for trans-epidermal delivery of cosmeceuticals products into the skin. This delivery method can enhence the effect of the substances on the skin and boost my results. IMPACT is an additional step after treatment with the ProScan applicator.
-
The main indications of the Alma Hybrid are:
Skin resurfacing, Wrinkles, rhytids, and furrows (including fines lines and texture irregularities), Skin laxity, Scar revision (burn & traumatic),Surgical scars, Acne scars, Uneven pigmentation/ dyschromia/ pigmentation improvement, Melasma (with the fractional technology), stretch marks (striae), and many more skin conditions. -
Alma Hybrid is a unique medical device that utilizes three technologies-
- Co2 10600nm laser
- 1570nm Fiber laser
- IMPACT patented Ultrasound technology for Trans Epidermal Delivery
Our ProScan applicator with the HyGrid mode of action, gives you the benefit of both the lasers in one applicator, enables you to custom-program the skin ablative -non ablative ratio in a matrix of the precise proportions required to meet the unique treatment needs of each patient.
-
Alma Hybrid™ combines the power of ablative and non-ablative lasers for a wide range of treatments, creating a uniquely synergistic effect. These unique hybrid combination of lasers enables you to create a tailor-made treatment for a variety of indications with controled downtime to suit your patients needs and schadual.